vulcanarm.ae

أدوات معدات

Portable Hydraulic Tester

1. Operating temperature: -40°C to +50°C;
2. Storage temperature: -43°C to +70°C;
3. Relative humidity: 95% (35°C ±3°C);
4. Maximum operating altitude: no less than 5,500 meters
5. Shock: Half-sine pulse, peak acceleration of 20g, pulse width of 11ms, three impacts on the working surface.
6. Vibration: Frequency range 5Hz to 5.5Hz, displacement (double amplitude) of 25.4mm; frequency range 5.5Hz to 200Hz, acceleration of 1.5g, scan time of 12 minutes, maximum test time of 24 minutes.
7. Temperature measurement range: -45°C to +100°C; accuracy: ±1°C;
8. Pressure measurement range: 0 MPa to 25 MPa; accuracy: ±0.5% FS;
9. Solid contamination measurement range: 0 to 12 levels; accuracy: ±1 level;
10. Motion viscosity measurement range: 1 mm²/s to 800 mm²/s; accuracy: ±2% FS;
11. Dielectric constant measurement range: 1.0 to 6.0; accuracy: ±2% FS;
12. Hydraulic tester main unit weight: 7.68 kg;
13. Main unit dimensions: 356 mm (length) × 284 mm (width) × 86 mm (height);
14. Continuous operating time: >12 hours (when powered by an external power supply); >2 hours (when powered by the built-in battery at room temperature);
15. Power supply compatibility: DC 26 V ±4 V, AC 220 V mains power;
16. Electromagnetic compatibility: Complies with the requirements of GJB151B-2013 “Electromagnetic Emission and Sensitivity Requirements and Measurement for Military Equipment and Subsystems” for CE102, CS101, CS114, CS115, CS116, RE102, and RS104;
17. Reliability: MTBF > 3000 hours;

Details